玻化微珠再生混凝土柱外墙角部位的P-Temp计算分析
《延边大学学报(自然科学版)》[ISSN:1004-4353/CN:22-1191/N]
卷:
第41卷
期数:
2015年04期
页码:
343-347
栏目:
应用科学研究
出版日期:
2015-12-20
- Title:
- Analysis of P-Temp for glazed hollow beads of recycled concrete columns
- 文章编号:
- 1004-4353(2015)04-0343-05
- 关键词:
- 玻化微珠再生混凝土柱; P-Temp分析; 热桥线传热系数
- Keywords:
- glazed hollow beads of recycled concrete columns; P-Temp analysis; heat transfer coefficient of thermal bridge line
- 分类号:
- TU375.3
- 文献标志码:
- A
- 摘要:
- 为了量化分析玻化微珠再生混凝土柱应用于建筑构件与剪力墙时对围护结构中外墙角部的热桥现象的影响,利用二维温度场计算软件P-Temp进行了模拟分析,并且与多孔砖结合聚苯板的保温处理方法进行了对比.结果表明:在保温砂浆层为60 mm时,普通混凝土柱与玻化微珠再生混凝土剪力墙结合使用时的热桥线传热系数为0.14 W/(m·K),流出热量为13.462 W; 玻化微珠再生混凝土柱与玻化微珠再生混凝土剪力墙结合使用时的热桥线传热系数为-0.11 W/(m·K),流出热量为8.564 W,且流出热量均小于采用多孔砖外贴
- Abstract:
- For quantitative analysis of vitrified microsphere, recycled concrete column is applied to the construction component and shear wall for retaining structure home and abroad, the corner of the influence of thermal bridge phenomenon, using two dimensional temperature field calculation software P-Temp calculation, and combined with porous brick of polystyrene insulation processing analysis. Results showed that the thermal insulation mortar layer is 60 mm, ordinary concrete column and vitrified microsphere, recycled concrete shear wall when combined heat transfer coefficient of thermal bridge line up to 0.14 W/(m·K), flow quantity of heat is 13.462 W; with vitrified microsphere, recycled concrete column and vitrified microsphere, recycled concrete shear wall when used in combination, the thermal bridge line heat transfer coefficient is 0.11 W/(m·K), the heat flow is only 8.564 W, and the combination of heat flow are less than use with porous brick. Visible vitrified microsphere, recycled concrete is applied to building palisade structure has certain superiority, is conducive to building energy efficiency design.
参考文献/References:
[1] 王晶,沈勇嵬.结构性热桥的线传热系数对建筑节能设计计算的影响[J].建筑节能,2014(2):56-64.
[2] 张泽平.玻化微珠保温混凝土及其结构的基本性能试验与理论分析研究[D].太原:太原理工大学,2009.
[3] 吴迪.高温作用后玻化微珠保温混凝土梁柱构件的承载力分析[D].太原:太原理工大学,2013.
[4] 赵志安.严寒和寒冷地区居住建筑节能设计软件中的热桥传热计算[C]//第十七届全国工程建设计算机应用大会论文集.中国土木工程学会计算机应用分会、中国建筑学会建筑结构分会计算机应用专业委员会,2014:4.
[5] 何俊霖.XKD泡沫混凝土墙热桥构造及传热系数简化算法[J].山西建筑,2011,18:187-188.
[6] 赵立华,秦翠翠.墙体平均传热系数计算时梁柱的计算方法探讨[C]//城市化进程中的建筑与城市物理环境:第十届全国建筑物理学术会议论文集.中国建筑学会建筑物理分会,2008:5.
[7] 李珠.玻化微珠保温材料的系列研究与城市窑洞式绿色建筑[M].北京:北京邮电大学出版社,2011.
备注/Memo
通信作者: 李佰寿(1954—),男,博士,教授,研究方向为混凝土结构理论及应用.
更新日期/Last Update:
2015-12-20